← Technical document library Technical data sheet

One-Way Mirror Glass Technical Data Sheet — Observation Rooms

One-way vision mirror glass for observation and privacy rooms: optical target grades, bright/dark lighting ratio, installation guidance and custom fabrication.

Model / constructionOne-Way Mirror Glass — Low and Higher Transmission
Document referenceNOG-TDS-OWM-V1.0
Revision1.0
Issue date2026-10-21
Illustrative one-way-mirror diagram with a bright room and a dim observer room
Illustrative technical diagram, not an image of an actual production batch or laboratory result.

Optical and material specifications

Parameter Reference / design target Evidence or qualification required
Grade convention Low-transmission (~15% VLT) and higher-transmission (~35% VLT) options Commercial SKU naming to be confirmed with each quotation
Low-transmission option: visible transmission 12–15% — indicative reference Indicative value; test with the specified thickness
Low-transmission option: coated-side reflection 65–70% — indicative reference Confirm reflection-side value from a dated sample report
Higher-transmission option: visible transmission 30–35% — indicative reference Indicative value, confirm with sample
Higher-transmission option: coated-side reflection 45–50% — indicative reference Specify reflected side and measurement conditions
Substrates Clear / low-iron / tinted float glass for selected designs Optical values change with substrate and thickness
Lighting differential 8:1–10:1 design starting point, not a pass/fail standard Prototype with actual room layout; 10:1 is a conservative privacy design target

Data interpretation: Published design targets and reference values are not signed acceptance tolerances. Final performance depends on substrate, coating construction, thickness and actual test conditions; customer acceptance criteria are confirmed against an approved sample and the relevant report.

Sizes, coating route and processing

Production and quality responsibility

North One Glass operates glass cutting, precision edge finishing, physical tempering and laser machining capabilities in China. Vacuum sputter coating is produced on qualified equipment, including NorthGlass-operated coating lines. North One defines application requirements, reviews coating feasibility, validates samples, performs in-house glass processing, inspects finished goods and delivers export orders. Specialist constructions require a separate process review.

Dimensional and processing capability — scope of claim

Scope Capability / qualification
Glass substrate Clear or low-iron float glass; tinted substrates for selected products; availability depends on coating family
Thickness 1.1–19 mm coating capability for selected processes; common listed options vary by product and are not all stocked
Frequently requested sheet formats 915 × 1220, 1830 × 1220, 1830 × 2440, 2140 × 3300, 2250 × 3660 and 2440 × 3660 mm; availability must be checked for the chosen grade
Large-format reference Up to 3300 × 19000 mm is a product-dependent, special-order route referenced in existing catalog material; not routine stock
In-house processing Cut-to-size, straight/precision edge polishing, selected shape work, physical tempering and laser cutting/drilling where applicable
Additional processing Specialty sputter coating, lamination, IGU construction, screen printing, curved fabrication and specialty testing as individually qualified
Delivery form Raw coated sheet, cut-to-size panel or processed glass after design and process review

Large-format coating, heat treatment, flatness, lifting, packing and international transport are separate feasibility checks. The maximum coating size must not be interpreted as the maximum temperable, laminated or shippable panel size.

Application-specific engineering cautions

  • Installation must maintain the brighter/darker room relationship across day and night.
  • Both coated-side and glass-side reflection should be specified when room orientation matters.
  • Glass alone does not guarantee privacy; evaluate lighting layout and the final assembled room.

Inspection, reports and acceptance

North One applies incoming material checks, in-process inspection, final outgoing inspection and batch traceability appropriate to the order. Optical transmission/reflection and color can be measured or commissioned through qualified laboratories; the method, wavelength range, angle of incidence, measurement side, substrate, instrument and tested configuration must appear on the actual report.

  • Optical: EN 410 / ISO 9050 may be used where relevant to the specified quantity. A numerical claim is binding only when the sample/lot report states the applicable method and configuration.
  • Surface/coating: Visual quality, adhesion, abrasion and chemical resistance tests are agreed against the application and documented method; a cycle count or service-life prediction is not implied by the coating technology itself.
  • Processed glass: Edge finish, dimensions, holes and tempered/laminated safety requirements are checked against the drawing and applicable project standards. Passing a coating test does not by itself certify a finished safety-glass assembly.
  • Evidence: Batch records, available spectra, relevant laboratory reports and applicable compliance documents can be supplied for review when available. No blanket certification or warranty is asserted by this data sheet.

Technical notice: Values identified as indicative reference or nominal design target are for initial selection. Final specifications, warranties and conformity claims are agreed in the signed technical specification, order documentation and relevant test reports.