Match the quantity to the measurement
Transmission, reflection, haze, colour and ultraviolet protection describe different quantities. A reference percentage is meaningful with its wavelength range, calculation basis and tested construction. EN 410 or ISO 9050 may be used where applicable to the agreed quantity; cite the actual method and edition on the report.
Record the test conditions
| Record | What to identify |
|---|---|
| Sample | Model, batch or sample reference, substrate, thickness and final construction |
| Optical geometry | Incident angle, measured side, beam or aperture and polarization when relevant |
| Spectral measurement | Wavelength range, sampling interval, measured transmission / reflection curves and instrument identification |
| Calculation | Weighting, illuminant and averaging or integration method used for the reported quantity |
| Traceability | Laboratory or operator, measurement date and calibration / reference information |
Interpret the product correctly
- AR94 is a single-side anti-reflective route; an uncoated surface still contributes reflection. An AR transmission result does not establish UV protection.
- T70 / T65 optical beam splitter glass values are nominal optical targets. A teleprompter measurement should use its actual angle and polarization conditions.
- T30 / T50 mirror display glass describes nominal transmission / reflection balance. Touch compatibility also depends on the assembled screen and sensor system.
- One-way mirror glass observation performance depends on the lighting difference and room configuration. An optical percentage alone does not guarantee privacy.
- Dichroic glass colour changes with angle and illumination. Evaluate the approved sample under the intended conditions.
- First surface mirror series reflectance requires the wavelength band, angle, measured side and application-specific optical quality to be defined.
- Temperable mirror glass reference grades and separately developed high-reflectance variants have different acceptance criteria. Review heat-treatment compatibility and the finished assembly.
Request evidence that matches the specification
Use the document reference and selected model when requesting a sample / lot report or raw spectral data. Compare the same quantity, side, angle and construction. A laboratory report applies to its identified sample and scope; a concept diagram or reference TDS is a different document type.