← Technical document library Measurement methods

Measurement Methods & Data Interpretation

Understand the sample, optical geometry, spectral range and calculation basis behind a glass specification.

Revision1.0
Issue date2026-10-22

Match the quantity to the measurement

Transmission, reflection, haze, colour and ultraviolet protection describe different quantities. A reference percentage is meaningful with its wavelength range, calculation basis and tested construction. EN 410 or ISO 9050 may be used where applicable to the agreed quantity; cite the actual method and edition on the report.

Record the test conditions

Record What to identify
Sample Model, batch or sample reference, substrate, thickness and final construction
Optical geometry Incident angle, measured side, beam or aperture and polarization when relevant
Spectral measurement Wavelength range, sampling interval, measured transmission / reflection curves and instrument identification
Calculation Weighting, illuminant and averaging or integration method used for the reported quantity
Traceability Laboratory or operator, measurement date and calibration / reference information

Interpret the product correctly

  • AR94 is a single-side anti-reflective route; an uncoated surface still contributes reflection. An AR transmission result does not establish UV protection.
  • T70 / T65 optical beam splitter glass values are nominal optical targets. A teleprompter measurement should use its actual angle and polarization conditions.
  • T30 / T50 mirror display glass describes nominal transmission / reflection balance. Touch compatibility also depends on the assembled screen and sensor system.
  • One-way mirror glass observation performance depends on the lighting difference and room configuration. An optical percentage alone does not guarantee privacy.
  • Dichroic glass colour changes with angle and illumination. Evaluate the approved sample under the intended conditions.
  • First surface mirror series reflectance requires the wavelength band, angle, measured side and application-specific optical quality to be defined.
  • Temperable mirror glass reference grades and separately developed high-reflectance variants have different acceptance criteria. Review heat-treatment compatibility and the finished assembly.

Request evidence that matches the specification

Use the document reference and selected model when requesting a sample / lot report or raw spectral data. Compare the same quantity, side, angle and construction. A laboratory report applies to its identified sample and scope; a concept diagram or reference TDS is a different document type.